Fluoroscopy Shielding Design
Expert Radiation Protection Solutions
C-Arm, Cath Lab, and Mobile C-Arm Shielding Designs
Fluoroscopy systems produce continuous X-ray exposure, making the shielding design essential for ensuring radiation safety and regulatory compliance. Our expert shielding physicists help protect patients, medical staff, and the public from unnecessary radiation exposure while meeting NCRP, AAPM, and state health department regulations.
Why Fluoroscopy Shielding Design is Critical
Unlike standard radiography, fluoroscopy emits prolonged radiation, increasing the scatter radiation exposure. Proper shielding ensures compliance with state and federal regulations and minimizes exposure to healthcare workers and individuals in adjacent areas. Our custom shielding designs use optimized materials and layout configurations tailored to your facility’s needs.
Industries & Facilities We Serve
Our fluoroscopy shielding solutions are designed for:
-
Hospitals & Medical Imaging Centers – Ensuring patient and staff safety in high-usage fluoroscopy suites.
-
Outpatient Clinics & Surgery Centers – Providing shielding solutions for mobile and fixed fluoroscopic units.
-
Pain Management Centers – Shielding C-arm fluoroscopy rooms for guided injections and procedures.
-
Orthopedic & Sports Medicine Clinics – Ensuring safe fluoroscopy use during diagnostic and therapeutic procedures.
-
Veterinary Clinics – Protecting staff and the general public from radiation exposure during imaging.
Each facility requires a customized shielding approach to ensure compliance and optimize protection. High-volume fluoroscopy centers may need reinforced barriers, while outpatient clinics may require more flexible shielding solutions.
Our Fluoroscopy Shielding Design Process
-
Radiation Source Analysis – Evaluating the X-ray output, beam energy, and exposure duration.
-
Shielding Calculations – Determining the necessary thickness and type of shielding material based on usage and occupancy factors.
-
Regulatory Compliance Assurance – Ensuring all designs meet NCRP Report No. 147, AAPM, and local health department standards.
-
Blueprint & Architectural Integration – Providing detailed shielding reports for contractors and architects.
-
Final Radiation Surveys – Conducting post-installation assessments to verify shielding effectiveness and compliance.
Fluoroscopy Shielding Materials & Solutions
We provide a variety of shielding materials tailored to fluoroscopy rooms:
-
Lead-lined drywall and lead sheet barriers for walls and ceilings.
-
Lead shielding doors and observation windows to maintain radiation protection while allowing visibility.
-
Lead acrylic or lead glass shields for operator protection.
-
Ceiling-mounted lead drapes and mobile barriers for flexible shielding during procedures.
-
Concrete and high-density materials for shielding high-energy fluoroscopy systems.
Regulatory Compliance & Shielding Standards
Meeting fluoroscopy shielding requirements is crucial to passing inspections and avoiding regulatory fines. Our team ensures that every design meets the necessary guidelines set by:
-
National Council on Radiation Protection and Measurements (NCRP)
-
American Association of Physicists in Medicine (AAPM)
-
Nuclear Regulatory Commission (NRC)
-
State Health Departments & Radiation Control Programs
Proper compliance documentation, including detailed shielding reports and verification testing, is provided for seamless approval by regulatory authorities.
Key Considerations in Fluoroscopy Shielding Design
-
Equipment Positioning & Usage – Optimizing shielding placement based on beam orientation and patient positioning.
-
Occupancy Classification – Assessing exposure risks for adjacent areas and ensuring adequate protection.
-
Radiation Workload Assessment – Determining shielding requirements based on daily usage and exposure duration.
-
Material Selection & Cost Efficiency – Choosing the best materials for long-term protection while maintaining budget efficiency.
-
Regulatory Documentation & Compliance Support – Ensuring that all required shielding reports are prepared for approval by the state health department.
Fluoroscopy Shielding for Different Applications
Shielding requirements vary depending on the type of fluoroscopy system in use:
-
Fixed Fluoroscopy Units – Permanent rooms require lead-lined walls, floors, and ceilings to contain scatter radiation.
-
Mobile C-Arm Fluoroscopy – Shielding strategies focus on wall, floor, and ceiling protection.
-
High-Dose Procedures (e.g., Interventional Radiology) – Additional shielding is required for prolonged exposures.
-
Veterinary Fluoroscopy – Specialized designs account for animal sizes and equipment positioning.
Long-Term Radiation Protection Strategies
Investing in proper fluoroscopy shielding design not only ensures immediate compliance but also provides long-term safety. We offer ongoing radiation safety assessments to ensure shielding remains effective as usage and technology evolve.
Request a Fluoroscopy Shielding Design Today
Whether you are constructing a new fluoroscopy suite or upgrading an existing one, our team provides accurate shielding calculations, expert guidance, and full regulatory compliance support. Contact us today to schedule a consultation and ensure your fluoroscopy shielding meets the highest safety standards.